Some Control Solutions Battery Chargers equipped with external LEDs are capable of displaying error codes. When an error is detected, the LED will flash a 2 digit sequence of numbers indicating the diagnostic code. The flashing occurs in this order: - The LED/user/throttle interface will flash a number of times indicating the first number of the code.
- A 1 second pause.
- The LED/user/throttle interface will flash a number of times indicating the second number of the code.
- A pause for 5 seconds and then the flash sequence will repeat the error code.
| |
To troubleshoot the problem follow these steps: - Write down the error code as determined from the procedure above.
- Find the error code in the table below.
- Follow the Corrective Steps in the table to resolve the problem.
- if the Corrective Steps do not solve your problem, contact Control Solutions Technical Support for help.
| Error Codes | Problem | Possible Causes | Corrective Steps | | | | | | | 4-2 | Charge Mode Timeout | The charge cycle did not complete within 24 hours. | 1. Check the battery charger and its connections for problems.2. The batteries should be inspected for problems by a qualified technician. | | | | | | | 4-3 | Charger Over Temperature | The charger overheated during the charge cycle (valid for CS1204 charger only). Check the battery and charger for problems. | 1. The batteries should be inspected for problems by a qualified technician.2. Battery charger is faulty. |
|